HR-IM-P Housing Rings - HR-IM-P-40

Product Description
Axially Assembled, Internal, ANSI Metric
Once installed in the groove of a housing/bore, the portion of the ring protruding from the groove (also called a “shoulder”) holds an assembly in place.
*F.I.M. (Full Indicator Movement) – Maximum allowable deviation of concentricity between groove and shaft.
For plated rings, add 0.05 to the listed maximum thickness. Maximum thickness will be a minimum of 0.005 less than the listed groove width (W) minimum.
Housing Dia. (Ds In.) | Housing Dia. (Ds mm) | Groove Dia. (Dg and Tol.) | Groove Width (W and Tol.) | Ring Free Dia. (Df and Tol.) | Ring Thickness (T and Tol.) | Groove Dia. (F.I.M.*) | Wt. Per 1000 pcs. | Released In Groove (L2) | Compressed in Housing (L1) |
---|---|---|---|---|---|---|---|---|---|
1.575 | 40 | 42.4 (+0.2) | 1.75 (+0.2) | 44.25 (+0.9/-0.65) | 1.6 (±0.08) | 0.15 | 4 | 31.6 | 29.2 |